== Data Acquisition == * {{{ sampling rate }}} Acquired samples per second by the daq card. * {{{ SubdeviceID for AIn eye position recording (16ch) }}} The ID of the analog input subdevice (find out via {{{comedi_test -t info}}}). * {{{ SubdeviceID for DIn spike recording (24ch) }}} The ID of the digital input subdevice (find out via {{{comedi_test -t info}}}). If no spikes or comparable digital signals are to be recorded, set this value to -1. * {{{ SubdeviceID for other DIO (8ch) }}} The ID of the digital in-/output subdevice (find out via {{{comedi_test -t info}}}). The trial trigger is on channel 0 output. The other channels may be used for response buttons, reward signals, LEDs and similar things. == Experiment file == * {{{ Experiment file }}} Path and filename of the last experiment configuration used. Usually this is not modified here. == Eye position module == === Calibration === * {{{ Channel 0 }}} Currently used horizontal calibration coefficients. These are the 6 coefficients a,b,c,d,e,f in the voltage (x) to gaze_angle funtion:<<BR>> ganze_angle = a + b * x + c * y + d * x^2^ + e * x * y + f * y^2^.<<BR>> Usually this is not modified here. * {{{ Channel 1 }}} Currently used vertical calibration coefficients. These are the 6 coefficients a,b,c,d,e,f in the voltage (x) to gaze_angle funtion:<<BR>> ganze_angle = a + b * x + c * y + d * x^2^ + e * x * y + f * y^2^.<<BR>> Usually this is not modified here. * {{{ # Channels }}} Number of channels used for eye position calibration. Use 1 for x-only mode or 2 for x-y-mode. * {{{ # Coefficient/channel }}} Number of calibration coefficients per channel. Order of the polynomial in the above equations. Currently only a value of 6 is implemented. === Input hardware === * {{{ # Channels }}} Number of channels used for eye position measurement. Currently only a value of 2 is implemented.<<BR>>Usually this is not modified here. * {{{ Device ID }}} Device ID for eye movement data acquisition. Usually 0. * {{{ Subevice ID }}} Subdevice ID for eye movement data acquisition. Usually equals DAQ/SUBDEVICE_ID_AIN. * {{{ X Channel ID }}} ID of channel for horizontal eye position. Usually 0. * {{{ Y Channel ID }}} ID of channel for vertical eye position. Usually 1. {{{... to be continued}}} |
Documentation of nrec Parameters
1. Data Acquisition
sampling rate
- Acquired samples per second by the daq card.
SubdeviceID for AIn eye position recording (16ch)
The ID of the analog input subdevice (find out via comedi_test -t info).
SubdeviceID for DIn spike recording (24ch)
The ID of the digital input subdevice (find out via comedi_test -t info). If no spikes or comparable digital signals are to be recorded, set this value to -1.
SubdeviceID for other DIO (8ch)
The ID of the digital in-/output subdevice (find out via comedi_test -t info). The trial trigger is on channel 0 output. The other channels may be used for response buttons, reward signals, LEDs and similar things.
2. Experiment file
Experiment file
- Path and filename of the last experiment configuration used. Usually this is not modified here.
3. Eye position module
3.1. Calibration
Channel 0
Currently used horizontal calibration coefficients. These are the 6 coefficients a,b,c,d,e,f in the voltage (x) to gaze_angle funtion:
ganze_angle = a + b * x + c * y + d * x2 + e * x * y + f * y2.
Usually this is not modified here.
Channel 1
Currently used vertical calibration coefficients. These are the 6 coefficients a,b,c,d,e,f in the voltage (x) to gaze_angle funtion:
ganze_angle = a + b * x + c * y + d * x2 + e * x * y + f * y2.
Usually this is not modified here.
# Channels
- Number of channels used for eye position calibration. Use 1 for x-only mode or 2 for x-y-mode.
# Coefficient/channel
- Number of calibration coefficients per channel. Order of the polynomial in the above equations. Currently only a value of 6 is implemented.
3.2. Input hardware
# Channels
Number of channels used for eye position measurement. Currently only a value of 2 is implemented.
Usually this is not modified here.
Device ID
- Device ID for eye movement data acquisition. Usually 0.
Subevice ID
- Subdevice ID for eye movement data acquisition. Usually equals DAQ/SUBDEVICE_ID_AIN.
X Channel ID
- ID of channel for horizontal eye position. Usually 0.
Y Channel ID
- ID of channel for vertical eye position. Usually 1.
... to be continued